Hi

Feel free to inquire!

We provide professional product solutions and will respond to your inquiry within 24 hours.

  • Ultra-low Temperature Water Circulation
Ultra-low Temperature Water Circulation
+

Description

Product Description

Special air-source heat pump exclusively developed for severe cold regions in northern China.It adopts a medium-pressure injection scroll compressor with enhanced vapor injection (EVI), breaking the low-temperature limitations of conventional air-source heat pumps. It can operate safely and stably in an ultra-wide ambient temperature range of -38℃~ 45℃, while providing both space heating + domestic hot water, and can directly replace traditional wall-hung boilers.

This is the RMDRN-DW Series, covering models from 03DW to 30DW.

  • Heating capacity under normal conditions: 9.87kW – 112.6kW
  • Heating capacity under ultra-low temperature conditions: 3.51kW – 44.5kW
  • Standard hot water output: 246L/h – 2337L/h
  • Suitable for both heating and hot water demands of various scales.

Core advantage

  • Excellent ultra-low temperature heating performance; operates without auxiliary heaters at -38℃, suitable for all northern regions.
  • Dual supply of space heating and domestic hot water, one unit for two purposes. Replaces traditional combination of wall-hung boiler and electric water heater, saving equipment cost and installation space.
  • Intelligent temperature control + automatic fault detection, real-time running status display, early fault warning, easy operation.
  • Equipped with enhanced vapor injection (EVI) compressor and internal grooved finned heat exchanger, maintaining high COP and high heating efficiency even under ultra-low temperature conditions.
  • Adopts coaxial / high-efficiency tank heat exchanger on the water side with strong pressure resistance, suitable for water systems in high-rise residences and large buildings.
  • Built-in winter water system anti-freeze protection, no additional anti-freeze measures required, ensuring more reliable and worry-free operation.

Usage scenario

Applicable scenarios for dual supply of heating and domestic hot water in severe cold northern regions: Underfloor heating / radiator heating for residential buildings, heating + hot water for hotels, heating + hot water for schools and hospitals, heating for office buildings of enterprises and public institutions, heating for industrial workshops, etc.

Q&A

Q1: Can the unit meet both the heating area demand and hot water supply at the same time? Will they interfere with each other? 

A1: Yes, it can satisfy both simultaneously without mutual interference. The unit features a dedicated water circulation design with independent heat exchange circuits for heating and hot water. It can fulfill both underfloor heating / radiator heating and domestic hot water supply at the same time. Different models are available for various heating areas and water consumption scales.

Q2: Will the heating efficiency drop significantly at an ultra-low temperature of -38℃?

A2: No. The unit is equipped with an enhanced vapor injection (EVI) scroll compressor. Under ultra-low temperature conditions, the vapor injection technology boosts heating capacity and COP. Compared with ordinary ultra-low temperature air-source heat pumps, the heating efficiency is improved by more than 30%, ensuring stable heating performance.

Q3: If I already have heating pipes from a traditional wall-hung boiler at home, do I need to renovate the pipes when replacing with this unit?

A3: No pipe renovation is needed. The water system interfaces of Jubang ultra-low temperature water circulation units are fully compatible with traditional wall-hung boilers. It can be directly installed as a replacement, with simple renovation, short construction period and no disruption to normal use.

Q4: Will the water circulation system freeze during water cuts or unit shutdowns in northern winters? Is additional anti-freeze protection required?

A4: No freezing will occur. The unit has a built-in anti-freeze protection function for the water system in winter. When the water temperature in the pipes falls below the anti-freeze set point, the circulation pump and auxiliary heating will activate automatically to prevent freezing. No extra anti-freeze measures are needed.

Equipment Parameter

Product Model RMDRN-03DW RMDRN-05DW RMDRN-10DW RMDRN-15DW RMDRN-30DW
Normal Condition (Standard Type) Rated Heating Capacity 9.87KW 19.3KW 38.8KW 56.3KW 112.6KW
Rated Heating Input Power 2.42KW 4.65KW 9.4KW 13.5KW 26.2KW
Nominal Condition for Low-Temperature Type Rated Heating Capacity 7.67KW 13KW 26.5KW 41.85KW 83.7KW
Rated Heating Input Power 2.22KW 3.93KW 8.05KW 11.5KW 22.5KW
Low-Temperature Condition Heating Capacity 6.1KW 10.4KW 21.1KW 29KW 63.5KW
Heating Input Power 2.1KW 3.71KW 7.57KW 10.8KW 21.1KW
Ultra-Low Temperature Condition Heating Capacity 3.51KW 7.86KW 15.9KW 21.7KW 44.5KW
Heating Input Power 1.71KW 3.45KW 7KW 10.1KW 19.5KW
Standard Hot Water Output (40℃ Temperature Rise) 246L/h 428L/h 864L/h 1210L/h 2337L/h
Maximum Input Power 3.13KW 6.44KW 12.72KW 16.6KW 35.62KW
Maximum Outlet Water Temperature 55℃
Power Supply 220V/50Hz / 380V/3N~/50Hz 380V/3N~/50Hz
Compressor Type High-Efficiency Scroll Type (Enhanced Vapor Injection)
Refrigerant R22 R22 R22 R410A R410A
Air-Side Heat Exchanger Type Inner Grooved Fin Type
Water-Side Heat Exchanger Type Coaxial Heat Exchanger or High-Efficiency Tank Heat Exchanger
Connection Size DN25 DN25 DN40 DN40 DN50
Overall Size L 712mm  712mm  1413mm  1305mm  1860mm
B 712mm  712mm  763mm  915mm  915mm
H 860mm 1013mm 1435mm 1775mm 2215mm
Unit Weight 95kg 130kg 260kg 420kg 650kg
Noise 58dB(A) 60dB(A) 69dB(A) 68dB(A) 69dB(A)

Notes:

1. Nominal condition for standard type: Outdoor ambient temperature 20℃DB/15℃WB, inlet water temperature 15℃, outlet water temperature 55℃.

2. Nominal condition for low-temperature type: Outdoor ambient temperature 7℃DB/6℃WB, inlet water temperature 9℃, outlet water temperature 55℃.

3. Low-temperature condition: Outdoor ambient temperature -5℃DB/-6℃WB, inlet water temperature 9℃, outlet water temperature 55℃.

4. Ultra-low temperature condition: Outdoor ambient temperature -15℃DB/-16℃WB, inlet water temperature 9℃, outlet water temperature 55℃.

5. Specifications are subject to change without prior notice due to product improvements. Please refer to the nameplate for actual parameters.

Factory

Moscow Cold Chain Logistics Park
St. Petersburg Fresh Produce Distribution Center
Far East Cross-Border Bonded Cold Storage
Honors

资质荣誉

FAQ


Can you accept small quantities?

Yes, accept small quantity, fast delivery

Do you have pre-shipment inspection procedures?

Yes, we always test the products before delivery.

Can I take samples for testing?

Yes, samples can be sent for testing before bulk ordering.

When is the delivery time?

Inventory orders within 7-15 days, for oem and odm orders, the specific time depends on the actual situation.

What are the terms of payment?

Wire transfer or letter of credit, Western Union, Alipay, etc.

What is the minimum order quantity?

It depends on the product.


Previous

Next

  • Ultra-low Temperature Water Circulation
Ultra-low Temperature Water Circulation
+

Ultra-low Temperature Water Circulation

Special air-source heat pump exclusively developed for severe cold regions in northern China.

You still doubt it?  First get samples contact us!