  • Circulating air source heat pump water heater
Circulating air source heat pump water heater
+

Description

Product Description

Circulating air source heat pump water heater is a basic type of air energy hot water equipment. It adopts a circulating heating mode consisting of the main unit, water tank pipelines and water pump. Cold water is continuously circulated and heated in the system before being stored in an insulated water tank, enabling constant hot water supply. 

The product range covers all models from RMDRN-02SR to RMDRN-30SR, with a rated hot water output of 150L/h to2380L/h, suitable for different water usage scales of 30 to 600 people. 

Under working conditions of 20℃dry bulb and 15℃wet bulb, the rated water outlet temperature is 55℃, and can reach up to60℃. The unit can operate stably in an ambient temperature range of-10℃to 45℃. 

Core advantage

  • Easy engineering installation, low operation and maintenance cost, no special machine room required, flexible installation scenarios. 
  • Integrated design with power-off automatic memory function; automatically restarts when power resumes, no on-duty personnel needed. 
  • Microcomputer automatically activates defrosting at low ambient humidity, adapting to various climates. 
  • Energy consumption is only 1/4 of electric water heaters, high efficiency, energy-saving and eco-friendly. Unit operating noise≤71dB(A), low noise operation. 
  • Class I anti-electric shock protection, IPX4 waterproof rating, rated water pressure 0. 7MPa, high safety protection and long service life. 

Usage scenario

Mainly applicable to small and medium-sized collective places with stable hot water demand, including factory dormitories, hotels, saunas&foot massage shops, school bathrooms, staff baths of small and medium-sized enterprises and public institutions, etc. 

Q&A

Q1: How does this model adapt when the number of water users increases temporarily? 

A1: A single unit is suitable for a fixed water usage scale. Capacity expansion can be achieved by combining multiple units. The system has strong compatibility and will not affect the operation of original equipment. 

Q2: Do I need to reset the hot water temperature manually after power is restored? 

A2: No manual reset is needed. The unit is equipped with an automatic power-off memory function. It will automatically restore the operation parameters and temperature settings before power failure once power is back. 

Q3: Can this model work normally in northern winters when the temperature is below-10℃? 

A3: The normal stable operating temperature range of this model is-10℃to 45℃. If the temperature in northern winters stays below-10℃continuously, we recommend using an auxiliary heater or switching to our ultra-low temperature series to ensure hot water output and heating performance. 

Q4: What daily maintenance is required for the equipment, and is it complicated? 

A4: Daily maintenance only includes regularly checking whether the circulation pump and pipelines are unobstructed, and cleaning dust from the surface of the heat exchanger fins. The unit has a built-in fault recording function, allowing you to directly view the operation status via the control panel, so no complicated professional maintenance is needed. 

Equipment Parameter

Product Model RMDRN-02SR RMDRN-03SR RMDRN-03SR RMDRN-05SR RMDRN-07SR RMDRN-10SR RMDRN-12SR RMDRN-15SR RMDRN-20SR RMDRN-25SR RMDRN-30SR
Rated Hot Water Output 150L/h 200L/h 200L/h 420L/h 560L/h 810L/h 960L/h 1190L/h 1682L/h 2106L/h 2380L/h
Rated Heating Capacity 6KW 9.3KW 9.3KW 19.5KW 26KW 38KW 45.5KW 52.5KW 78.25KW 98KW 110KW
Rated Input Power 1.51KW 2.2KW 2.2KW 4.2KW 5.4KW 8.8KW 10KW 12.3KW 17KW 21.2KW 24.6KW
Maximum Input Power 2.5KW 3.5KW 3.5KW 6.8KW 7.8KW 10.8KW 14KW 17.3KW 22KW 32KW 34.3KW
Rated Input Current 7.5A 11A 5.6A 8A 9.5A 17A 21.3A 24A 30A 38A 48A
Maximum Input Current 12.5A 14.5A 10A 13A 16A 25.2A 28A 37.1A 46A 57.8A 71.6A
Water Outlet Temperature Rated Temp.: 55℃ / Max. Temp.: 60℃
Rated Power Supply 220V-/50Hz 380V 3N-/50Hz
Anti-electric Shock Class Class I                                                                                      Waterproof: IPX4
Rated Water Pressure 0.7MPa                                                                                                Ambient Temp.: -10℃~45℃
Noise Level ≤55dB(A) ≤60dB(A) ≤60dB(A) ≤62dB(A) ≤65dB(A) ≤68dB(A) ≤68dB(A) ≤68dB(A) ≤65dB(A) ≤65dB(A) ≤71dB(A)
Main Unit Connection Size DN20 DN25 DN25 DN25 DN25 DN40 DN40 DN40 DN50 DN50 DN65
Unit Weight 60kg 88kg 88kg 130kg 160kg 280kg 320kg 420kg 510kg 608kg 890kg
Overall Size L 1030mm 712mm  712mm  752mm  727mm 1430mm 1384mm 1510mm 1828mm 1828mm 2300mm
B 320mm 712mm  712mm  752mm  727mm 735mm 805mm 800mm 1038mm 1038mm 1100mm
H 620mm 860mm 860mm 1100mm 1013mm 1100mm 1013mm 1400mm 1400mm 1400mm 1900mm
Applicable Users 30~50 persons 50~100 persons 50~100 persons 80~120 persons 100~150 persons 150~200 persons 200~250 persons 250~300 persons 300~400 persons 400~500 persons 500~600 persons

Notes:

1. The above data is tested under conditions of dry bulb temperature 20℃, wet bulb temperature 15℃, inlet water temperature 15℃, and outlet water temperature 55℃.

2. With technological advancement, our products are continuously improved and updated. Parameters are subject to change without prior notice, and the data on the product nameplate shall prevail.

Factory

Moscow Cold Chain Logistics Park
St. Petersburg Fresh Produce Distribution Center
Far East Cross-Border Bonded Cold Storage
Honors

资质荣誉

FAQ


Can you accept small quantities?

Yes, accept small quantity, fast delivery

Do you have pre-shipment inspection procedures?

Yes, we always test the products before delivery.

Can I take samples for testing?

Yes, samples can be sent for testing before bulk ordering.

When is the delivery time?

Inventory orders within 7-15 days, for oem and odm orders, the specific time depends on the actual situation.

What are the terms of payment?

Wire transfer or letter of credit, Western Union, Alipay, etc.

What is the minimum order quantity?

It depends on the product.


Previous

Next

  • Circulating air source heat pump water heater
Circulating air source heat pump water heater
+

Circulating air source heat pump water heater

Circulating air source heat pump water heater is a basic type of air energy hot water equipment. It adopts a circulating heating mode consisting of the main unit, water tank pipelines and water pump.

You still doubt it?  First get samples contact us!